Hello Tobias,

 

 

This is the reason:

 

WaitForInstanceShutdown: Instance 91 of system <sid> not down after 120 seconds.           

 

 

Your central Instance needs to long to shutdown, so the whole procedure stopps.

 

It is a known 'problem', because JAVA needs a long time to start and to shut down.

 

Please increase the waittime accordingly

     Wait for instance to end . . . . WAIT         > *YES        

     Maximum wait time (seconds)  . . WAITTIME     > 600     

and try again.

 

Best regards